Server rooms and data centers are the heart of every digital operation — hosting servers, UPS systems, networking racks, and critical IT infrastructure.
Even a small electrical fire can cause:
?? Data loss & extended downtime
? Damage to expensive servers & UPS systems
?? Massive financial loss due to outages
?? Compliance & legal risks (especially for BFSI, IT/ITES, and telecom sectors)
According to NBC India (Part 4) and NFPA 75 & 2001, automatic fire suppression systems are mandatory in data rooms to ensure fast detection and immediate extinguishing without damaging sensitive equipment.
?? Short circuits in server racks or PDU boards
?? Overheating of UPS battery banks (especially lithium-ion)
?? HVAC or cooling system failures
?? Loose wiring & cable overloading
?? Static discharge or faulty power supplies
?? Dust accumulation and lack of proper maintenance
These environments demand non-conductive, residue-free suppression agents that can extinguish fires quickly without harming IT hardware.
The most preferred solution for server rooms & data centers.
How It Works:
A detection system (smoke/heat/aspirating) identifies the fire early.
The clean agent (Novec 1230 or FM-200) is released through nozzles.
It suppresses the fire by absorbing heat & disrupting the chemical chain reaction, without leaving residue.
? Advantages:
Safe for electronics and occupied spaces
Leaves no residue and requires no cleanup
Rapid total flooding (within seconds)
NFPA 2001 & NBC India approved
?? Popular in: Server rooms, data centers, UPS rooms, edge computing facilities.
Ideal for large data halls where long discharge time & oxygen displacement is required.
Uses natural gases like Nitrogen/Argon/CO2 mix
Environmentally friendly, zero ODP & GWP
Requires sealed rooms & pressure relief vents
?? Best suited for hyperscale data centers, telecom hubs & critical control rooms.
For individual server racks, UPS panels & edge cabinets.
Heat-sensitive detection tube installed inside cabinets
Bursts on heat rise, releasing agent directly at fire source
Compact, automatic & doesn’t require power supply
?? Ideal for distributed IT racks, remote edge sites, BTS rooms.
Component | Function |
---|---|
?? Fire Detection System | Early warning via smoke/heat detectors or aspirating (VESDA) |
?? Control Panel | Triggers alarm & suppression automatically |
?? Clean Agent Storage | Novec 1230 / FM-200 cylinders |
?? Discharge Network | Nozzles & piping for uniform agent distribution |
?? Room Integrity | Proper sealing to ensure flooding concentration |
?? Manual Release & Abort Switches | For safety & manual override |
?? Instant extinguishing before fire spreads
?? No damage to electronics or IT equipment
?? Environment-friendly (Novec 1230 has zero ozone depletion)
?? Low maintenance and long agent life
?? Minimal downtime post-discharge
?? Complies with NFPA, NBC India & IS standards
Fire Engineering Technology offers end-to-end server room & data center fire suppression systems, including:
? Novec 1230 & FM-200 gas flooding systems
? Inert gas total flooding systems
? Tube-based local suppression for racks & UPS
? Detection, control & integration with BMS/Fire Alarm
? Turnkey installation, testing, refilling & AMC Pan India
?? Trusted by data centers, IT parks, telecom operators, banks, and government agencies across India.
Fire suppression for data centers must comply with:
NBC India Part 4 – Fire & Life Safety
NFPA 75 & NFPA 2001 – IT Equipment & Clean Agent Systems
IS 15493 – Gaseous Fire Extinguishing Systems
Local Fire Department & FM Global guidelines
?? Non-compliance can lead to NOC rejection, insurance issues, and operational risks.
Server rooms & data centers demand specialized fire suppression systems that are fast, clean, and reliable.
By using Novec 1230 / FM-200 clean agent systems, inert gases, and tube-based localized protection, you can safeguard critical IT infrastructure and ensure business continuity 24×7.
?? Partner with Fire Engineering Technology, a leading fire suppression system manufacturer in India, for design, supply, installation & maintenance of certified, high-performance server room fire protection solutions.
Server room fire suppression India
Data center fire protection system
Novec 1230 gas flooding system India
FM-200 clean agent system for IT room
UPS room fire suppression solutions
Tube-based fire suppression for server racks
NBC India fire suppression system standards
Fire Engineering Technology fire protection
FAQs
Q1. Which fire suppression system is best for server rooms in India?
?? Novec 1230 and FM-200 clean agent systems are most effective and NBC/NFPA compliant.
Q2. Is Novec 1230 safe for IT equipment?
?? Yes, it’s non-conductive, residue-free, and safe for sensitive electronics.
Q3. Can tube-based suppression protect individual server racks?
?? Yes, it provides localized protection inside racks, ideal for distributed IT setups.
Modern server rooms and data centers are critical assets that require reliable fire suppression systems to prevent electrical fires, equipment damage, and downtime. Installing a server room fire suppression system or data center fire suppression system in India ensures automatic fire protection that meets NFPA, NBC, and IS standards.
The most popular solutions include Novec 1230 fire suppression systems, FM-200 clean agent systems, inert gas flooding systems, and tube-based fire suppression systems. These are ideal for UPS rooms, server racks, network panels, and IT data halls, offering non-conductive, residue-free, fast-acting fire protection. Clean agent fire suppression systems are preferred for total flooding applications in server rooms, ensuring rapid extinguishing with zero residue.
Tube-based fire suppression systems for server racks provide localized automatic protection and are easy to install, making them perfect for edge data centers, telecom rooms, and distributed IT infrastructure.
Fire Engineering Technology, a leading fire suppression system manufacturer in India, offers custom-engineered fire protection solutions, including Novec 1230 gas flooding systems, FM-200 systems, CO2 flooding systems, and automatic clean agent fire suppression for IT rooms.
Our solutions are trusted across data centers, IT parks, telecom sites, and industrial server rooms for 24×7 fire protection. Protect your critical infrastructure with high-performance server room fire suppression systems for maximum safety, regulatory compliance, and business continuity.
Want to know more about our products.. fill the form below