Punjab’s economy runs on high-throughput manufacturing, precision engineering, pharma, IT, logistics, and heavy industry. When a fire starts in a control panel, UPS room, lab, or data hall, seconds matter—and water or powder can ruin equipment, contaminate product, and cripple operations.
Fire Engineering Technology designs, manufactures, installs, and maintains clean agent fire suppression systems (FK-5-1-12/“Novec™ 1230” equivalent, HFC-227ea/FM-200®, inert gases like IG-541/IG-55) across Ludhiana, Amritsar, Jalandhar, Mohali (SAS Nagar), Rajpura, Dera Bassi, Mandi Gobindgarh, Bathinda, Patiala, Pathankot, and all PSIEC focal points.
Extinguish within seconds; stop incipient fires before flame impingement.
No residue; safe for electronics, tooling, and cleanrooms.
People-safe at design concentrations in occupied spaces (per standards).
Compliance-ready: NFPA 2001 / ISO 14520, NBC 2016 Part 4, local by-laws.
Pre-engineered direct-tubing panel systems (DLPS) for MCC/VCB/ACB, VFD, PLC, CNC, server racks.
Engineered total-flooding systems (FK-5-1-12 / HFC-227ea / IG-541 / IG-55) for rooms: server/UPS/LV-HV, control rooms, cleanrooms, labs.
High-sensitivity detection: Aspirating/ASD (VESDA-type), addressable smoke/heat, linear heat, rate-of-rise; cross-zoned release.
Release & interlocks: Abort, manual release, HVAC trip, damper closure, EPO, door holders, pre-discharge alarms, BMS/SCADA.
Room integrity & pressure relief: Door seals, PRVs, fan tests, post-discharge ventilation planning.
AMC & audits: Monthly/quarterly/annual checks, hydro-tests, function tests.
Below, every major sector gets: risks → compliance → recommended systems → design notes → quick wins.
Risks: Overheated servers, UPS faults, cable trays, raised floors.
Standards: NFPA 75/76 (IT), NFPA 2001/ISO 14520; NBC 2016.
Recommended:
FK-5-1-12 or HFC-227ea total-flooding for data halls, network rooms, NOCs.
ASD (aspirating) + cross-zoned addressable detection.
Inert gas for UPS/battery rooms (favorable in occupied areas).
Design notes: 10-second discharge; hold time verification; door seals + PRV; automatic HVAC shutdown & damper closure.
Quick wins: Add panel-level tubing for PDU/UPS cabinets to stop micro-events early.
Risks: Labs, solvent stores, cleanrooms (GMP), BMS/EMS panels.
Standards: cGMP/WHO GMP cleanroom requirements + NFPA 2001; Haz-area classification if solvents.
Recommended:
FK-5-1-12 or IG-541 flooding for cleanrooms, R&D, quality labs.
Direct-tubing for automation/control panels and isolators.
Design notes: Validate leakage/hold time; avoid residue; integrate BMS alarms, interlock AHU/pressurization.
Quick wins: Dedicated agent zoning for stability chambers, LAF cabinets (local protection).
Risks: MCC panel fires, lint/dust ignition, solvent use in finishing, boilers.
Standards: NFPA 33 (finishing), NFPA 2001; NBC.
Recommended:
Direct-tubing systems inside MCC/PLC/drive cabinets.
FK-5-1-12 flooding for E-rooms; local CO2 for unoccupied paint/curing booths.
Design notes: Combine with dust extraction & housekeeping; ASD in cable galleries.
Quick wins: Ring-main with master cylinder feeding grouped panels to reduce capex.
Risks: CNC cabinets, oil mist, robots, PLC racks.
Standards: NFPA 36/79 (machinery), NFPA 2001.
Recommended:
Tubing systems inside CNC/robot cabinets.
FK-5-1-12 flooding for control rooms, inspection labs, server closets.
Design notes: Seal cabinets; provide post-discharge purge; E-stops interlocked.
Quick wins: Linear heat detection on cable trays over production lines.
Risks: Substations, cable trenches, PLC/SCADA rooms, rolling mills.
Standards: NFPA 850 (power), NFPA 2001; IEC 60079 if flammables present.
Recommended:
Panel-level tubing for MCCs/VCB rooms.
Inert gas or CO2 local application for cable trenches (unoccupied).
Design notes: Avoid water where tripping risk is critical; ASD for early alarms.
Quick wins: Compartmentalize trenches; add damper-linked smoke extraction.
Risks: E-rooms, chargers, server closets; high-value goods.
Standards: Sprinklers for racking + NFPA 2001 for critical rooms.
Recommended:
Clean-agent flooding for HT/LT rooms, control rooms, WMS/IT racks.
Tubing systems for chargers/panel clusters.
Design notes: Keep sprinklers for storage; clean agents protect electronics and keep ops live.
Quick wins: ASD in E-rooms; audible/visual pre-discharge warnings.
Risks: Panel fires in cold rooms, compressors, automation.
Standards: NFPA 2001; hygiene/cold-store standards.
Recommended:
FK-5-1-12 flooding for compressor/PLC rooms (low residue, equipment-safe).
Tubing in panel suites.
Design notes: Sub-zero performance considerations; integrity testing for thick-insulated rooms.
Quick wins: Seal penetrations; monitor PRV icing potential.
Risks: Analyzer shelters, solvent stores, MCC/PLC, hazardous zones.
Standards: IEC 60079 (hazardous classification), OISD, NFPA 2001.
Recommended:
Inert gas in analyzer shelters & control rooms.
FK-5-1-12 for non-haz E-rooms.
Design notes: Explosion-proof detection hardware where required; purge & ventilation logic; earthing/bonding.
Quick wins: Redundant detection loops with manual release/abort outside the room.
Risks: LV/HV rooms, generator control, cable vaults.
Standards: NFPA 850/2001; utility SOPs.
Recommended:
Clean-agent flooding for control rooms; CO2 local (unoccupied) for cable vaults; tubing in switchgear.
Design notes: Fail-safe trips for breakers; integrate with SCADA.
Quick wins: ASD + thermal imaging program for predictive alarms.
Risks: Battery thermal events, inverter panels.
Standards: NFPA 855 (energy storage), NFPA 2001.
Recommended:
Inert gas for occupied battery rooms; FK-5-1-12 for inverter E-rooms.
Tubing in rack-enclosures.
Design notes: Gas detection (H2) where relevant; exhaust fans interlock.
Quick wins: Zoned release to limit agent quantity.
Risks: Server rooms, imaging suites, LT rooms.
Standards: NBC 2016; NFPA 2001.
Recommended:
FK-5-1-12 flooding for server/MRI control rooms; tubing for panels.
Design notes: Occupancy alarms; maintenance windows.
Quick wins: Door fan tests budgeted into CAPEX to avoid rework.
Risks: Data centers, command rooms, archives, strong rooms.
Standards: NIC/MeitY, NFPA 2001.
Recommended:
Inert/FK-5-1-12 flooding + ASD; redundant detection.
Design notes: Access control interlocks; post-drainage re-entry SOPs.
Quick wins: Integrate with BMS/IDS for single pane of glass.
Ludhiana: Focal Points; Industrial Areas A/B; Sahnewal, Doraha (textiles, auto, machine tools).
Jalandhar: Focal Points; sports goods & foundries clusters.
Amritsar: Industrial Area & Verka belt (textile/pharma).
Mohali (SAS Nagar): Mohali Industrial Area, Quark City IT Park, SEZ.
Mandi Gobindgarh: Steel cluster (rolling mills, induction furnaces).
Rajpura & Dera Bassi: Logistics, pharma packaging, engineering parks.
Bathinda, Patiala, Pathankot: Refinery/petrochem, textiles, agro/timber MSMEs.
Engineering calculations (agent mass, nozzle layout, flow/pressure).
Room Integrity Report (fan test) + PRV sizing.
Control logic: cause-and-effect matrix; interlock drawings.
FAT/SAT checklists, witnessed functional tests, discharge (as applicable).
As-built drawings, O&M manuals, MSDS, training records.
AMC plan (monthly/quarterly/annual) with logs, hydro tests, leak checks.
FK-5-1-12 (very low GWP) favored for sustainability.
Inert gases are naturally occurring (N2/Ar/CO2 mix).
HFC-227ea still common; plan for lifecycle & refill logistics per evolving regulations.
We supply UL/FM-approved components and follow best-practice handling & recharge.
At-a-Glance Mapping (handy table)
Sector | Rooms/Assets Protected | Agent Choice (typical) | Detection | Extras |
---|---|---|---|---|
IT/Data | Data halls, UPS, racks | FK-5-1-12 / 227ea; Inert for UPS | ASD + addressable | PRV, door seals, HVAC trip |
Pharma | Labs, cleanrooms, PLC | FK-5-1-12 / IG-541 | ASD + gas detection (where req.) | BMS/EMS links |
Textiles | MCC, finishing booths | Tubing + FK-5-1-12; CO2 (unocc.) | Linear heat + smoke | Local application nozzles |
Auto/Machine | CNC, robots, PLC | Tubing + FK-5-1-12 | ASD/spot + RoR | E-stops, purge fans |
Steel/Power | Substations, trenches | FK-5-1-12; CO2 (unocc.) | ASD + heat | SCADA interlocks |
Warehousing | E-rooms, WMS racks | FK-5-1-12 + Tubing | Spot + ASD | Works with sprinklers |
Petrochem | Analyzer/control | Inert + FK-5-1-12 | Gas + smoke | Ex-proof hardware |
Manufacturer-direct: faster lead times, better lifecycle cost.
Turnkey: survey → design → install → testing → AMC.
Local teams across Punjab for rapid response.
Proven in mission-critical environments (references available on request).
Book a free fire-risk survey anywhere in Punjab.
We’ll deliver a code-compliant design, drawings, and a fixed-price quote fast—so your production and uptime stay protected.
Want to know more about our products.. fill the form below